4 Bank Status Indicator
Lights:
The
following describes the operation of the status indicator lights:
►
AMBER -
When the amber light is on, the battery charger is in the process of fully
charging the battery. In order to properly charge large capacity
batteries, the charger may remain in this mode for several hours or even
days.
►
AMBER
FLASHING
- When the green light is flashing, and the red light is on, the battery
is greater than 80% charged and may be removed from the charger and used
if necessary. Leave the battery on charge until the green light is solid
whenever possible. Once the green light begins to flash, it will remain
flashing until either the battery charger output current drops below 0.1
amp, or until 6 hours has elapsed.
►
GREEN
- When the green light is lit, the battery charger is in the storage
mode of charge. In this mode the charger will maintain the battery
at full charge.
Stage 1) Bulk Charge:
Amber Light On, Green Light Off, Constant Current = 1.25 Amps,
Transition to Stage 2, Absorption Charge when battery voltage
reaches 14.4 VDC.
|
Stage 2) Absorption Charge:
Amber Light On, Absorption Voltage = 14.4
VDC
Transition to Float Charge when battery charging current drops below
0.1 amp or until 6 to 8 hours have elapses.
Stage 3) There is no Equalization Charge, Go directly to stage 4.
Stage 4) Float Charge:
Amber
Light Off, Green Light On.
Float Voltage = 13.2 VDC.
If an
external load is applied to the battery while the charger is in
stage 4, Float Charge, and if the battery voltage drops below a
range between 12.0 to 12.5 VDC, then the charge cycle restarts |
|
4
Bank Specifications: |
|
Nominal
Output: |
4
Independent DC Outputs |
|
Voltage: |
12 Volts |
|
Current: |
1.25 Amps |
|
Input
Voltage: (Universal Input) |
100 to 240
VAC |
|
Dimensions:
Charger Case |
8.8 (224) L
x 7.0 (178) W x 3.5 (89) H in (mm) |
|
Enclosure |
94VO Flame Retardant Polymer |
|
Weight Base
Unit w/o Accy |
2.75 lb
(1.25 kg) |
|
Carton Size |
13.5 (343) L
x 10.5 (267) W x 6.5 (165) H in (mm) |
|
Shipping
Weight |
Approximately 5 lbs. |
|
Agency
Listings: UL, ETL, CSA, etc. |
The Int’l BT
4-Bank Battery Mgmt System bears the CE mark and complies with both
UL-1236 and CSA 22.2. |
|
Up Choosing Tenders-Chargers Battery Tender Plus & Junior Intl. Waterproof Junior Output Cable Connections Battery Tender Twin Battery Tester Lightweight Power Tenders High Frequency Charger Heavy Duty & Dual Chargers Two Bank Charging Station Multiple Charging Stations Multiple Station Specifications International Plus & 4 Bank Intl. Plus & 4 Bank Specifications |
5
& 10 Bank Indicator
Lights:
The indicator
lights behave very much like the Battery Tender® Plus, except that
the RED light does not flash. The following describes the operation
of the status indicator lights:
►
AMBER -
When the amber light is on, it indicates that the AC POWER IS ON,
either 110 or 220 VAC, depending on the factory setting.
► RED
-
When
the red light is on, the battery charger is in the process of fully
charging the battery. In order to properly charge large capacity
batteries, the charger may remain in this mode for several hours or
even days.
►
GREEN
FLASHING - When the green light is flashing, and the red
light is on, the battery is greater than 80% charged and may be
removed from the charger and used if necessary. Leave the battery
on charge until the green light is solid whenever possible. Once
the green light begins to flash, it will remain flashing until
either the battery charger output current drops below 0.1 amp, or
until 8 hours has elapsed.
►
GREEN
- When the green light is lit, the battery charger is in the storage
mode of charge. In this mode the charger will maintain the battery
at full charge.
|
Stage 1) Bulk Charge:
Red
Light On, Green Light Off, Constant Current = 2.0 Amps, Transition
to Stage 2, Absorption Charge when battery voltage reaches 14.75 VDC.
Stage 2) Absorption Charge:
Red
Light On, Green Light Flashing, Absorption Voltage = 14.75 VDC
Transition to Float Charge when battery charging current drops below
0.1 amp or until 8 hours have elapses.
Stage 3)
There
is no Equalization Charge, Go directly to stage 4.
Stage 4) Float Charge:
Red
Light Off, Green Light On.
Float Voltage = 13.5 VDC.
If an
external load (greater than 2.0 amps) is applied to the battery
while the charger is in stage 4, Float Charge, and if the battery
voltage drops below a range between 12.0 to 12.5
VDC, then the charge cycle restarts. Each channel
can deliver the full 2.0 amp output while in float mode |
|
5 Bank Station Specifications: |
|
Size |
308 x 200 x
200 mm (12.13L X 7.88"W x 7.88"H) |
|
Weight |
7.25 kg. (16
lbs.) |
|
Enclosure |
Alumninum
Chassis |
|
Power
Requirements |
115 VAC @ 60
Hz (opt.220 @ 50 Hz) |
|
Output |
12V @ 2 Amps |
|
Output Cord
Length |
1.8 meters
(72") |
|
|
10 Bank Station Specifications: |
|
Size |
413 x 200
x 200mm (16.25"L x 7.88"W x 7.88"H) |
|
Weight |
10.0 kg
(22 lbs.) |
|
Enclosure |
Aluminum
Chassis |
|
Power
Requirements |
115 VAC @
60 Hz (opt. 220 @ 50Hz) |
|
Output |
12V @ 2
Amps |
|
Output
Cord Length |
1.8 meters
(72") |
|
| |
|
|